Инвентарный номер: нет.
   
   E 97


   
    Experimental study on start-up characteristics of loop heat pipes / H. X. Zhang, G. P. Lin, T. Ding, R. G. Sudakov, Yu. F. Maydanik // Scienein China Series E-Engineering & Materials Science. - 2005. - Vol. 48, № 2. - С. 131-144
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPE -- START-UP -- EXPERIMENT
Аннотация: This paper presents results of ground-experimental study on the start-up characteristics of a Loop Heat Pipe. The physical process of start-up is described, and the explanation that "Pressure Transfer" leads to the saturated temperature rise in compensation chamber during start-up is first discussed. Start-up behaviors as a function of various parameters including vapor/liquid distribution in the evaporator, adverse elevation, start-up heat load, sink temperature are described and explained. A peculiar start-up phenomenon composed of two start-up scenarios was first observed at adverse elevations and is described