Главная Новые поступления Описание Шлюз Z39.50

Базы данных


Труды сотрудников Института теплофизики УрО РАН - результаты поиска

Вид поиска

Область поиска
в найденном
Формат представления найденных документов:
полныйинформационныйкраткий
Отсортировать найденные документы по:
авторузаглавиюгоду изданиятипу документа
Поисковый запрос: (<.>K=EVAPORATOR<.>)
Общее количество найденных документов : 46
Показаны документы с 1 по 10
 1-10    11-20   21-30   31-40   41-46 
1.
Инвентарный номер: нет.
   
   T 44


   
    The proof-of-feasibility of multiple evaporator loop heat pipes / W. B. Bienert, D. A. Wolf, M. N. Nikitkin, Yu. F. Maydanik, Y. G. Fershtater, S. V. Vershinin, J. M. Gottschlich // 6th European Symposium on Space Environmental Control Systems: Noordwijk, Netherlands, 20-22 may 1997 . - 1997. - Vol.400. - С. 393-398
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPES -- THERMAL CONTROL -- MULTIPLE THERMAL INTERFACE
Аннотация: This paper presents results that demonstrate the proof-of-feasibility of multiple evaporator Loop Heat Pipes (LHP). It was demonstrated that a multiple evaporator LHP can successfully operate as a thermal control system component. A breadboard LHP with multiple evaporators (two) that retained the reliable self starting behavior of the single thermal interface LHP was developed. Program efforts were concentrated on a two pump system and investigated the performance of the dual evaporator LHP. Analytical predictons and experimental test data are compared, and important issues are discussed that will be a baseline for continued development of multiple thermal interface LHPs. All of the conclusions are based on test results, analytic modeling and the correlation of the two. Although a mathematical model that predicts the multiple evaporator LHP behavior was developed, the primary focus of the program was the development, fabrication, and test of a breadboard multi-evaporator LHP. The program clearly demonstrated that multi-evaporator LHPs are feasible and merit further development as a viable thermal control components

Найти похожие

2.
Инвентарный номер: нет.
   
   H 65


   
    High heat flux loop heat pipes / M. T. North, D. B. Sarraf, J. H. Rosenfeld, Yu. F. Maydanik, S. V. Vershinin // SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM (STAIF-97), PTS 1-3: 1ST CONFERENCE ON FUTURE SCIENCE & EARTH SCIENCE MISSIONS; 1ST CONFERENCE ON SYNERGISTIC POWER & PROPULSION SYSTEMS TECHNOLOGY; 1ST CONFERENCE ON APPLICATIONS OF THERMOPHYSICS IN MICROGRAVITY; 2ND CONFERENCE ON COMMERCIAL DEVELOPMENT OF SPACE; - 2ND CONFERENCE ON NEXT GENERATION LAUNCH SYSTEMS; 14TH SYMPOSIUM ON SPACE NUCLEAR POWER AND PROPULSION, ALBUQUERQUE, 26-30 JAN, 1997 . - 1997. - Vol.387. - С. 561-566
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPES -- THERMAL POWER LOADS -- VAPOR FLOW LOSSES
Аннотация: Loop Heat Pipes (LHPs) can transport very large thermal power loads, over long distances, through flexible, small diameter tubes and against high gravitational heads. While recent LHPs have transported as much as 1500 W, the peak heat flux through a LHP's evaporator has been limited to about 0.07 MW/m(2). This limitation is due to the arrangement of vapor passages next to the heat load which is one of the conditions necessary to ensure self priming of the device. This paper describes work aimed at raising this limit by threefold to tenfold. Two approaches were pursued. One optimized the vapor passage geometry for the high heat flux conditions. The geometry improved the heat flow into the wick and working fluid. This approach also employed a finer pored wick to support higher vapor flow losses. The second approach used a bidisperse wick material within the circumferential vapor passages. The bidisperse material increased the thermal conductivity and the evaporative surface area in the region of highest heat flux, while providing a flow path for the vapor. Proof-of-concept devices were fabricated and tested for each approach. Both devices operated as designed and both demonstrated operation at a heat flux of 0.70 MW/m(2). This performance exceeded the known state of the art by a factor of more than six for both conventional heat pipes and for loop heat pipes using ammonia. In addition, the bidisperse-wick device demonstrated boiling heat transfer coefficients up to 100,000 W/m(2) K, and the fine pored device demonstrated an orientation independence with its performance essentially unaffected by whether its evaporator was positioned above, below or level with the condenser

Найти похожие

3.
Инвентарный номер: нет.
   
   P 31


    Pastukhov, V. G.
    Adaptation of loop heat pipes to zero-g conditions / V. G. Pastukhov, Yu. F. Maydanik, Y. G. Fershtater // 6th European Symposium on Space Environmental Control Systems: Noordwijk, Netherlands, 20-22 may 1997 . - 1997. - Vol.400. - С. 385-391
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPES -- HEAT-TRANSPORT -- THERMOCAPILLARY PHENOMENA
Аннотация: Loop heat pipes (LHPs) posses a great variety of valuable properties, which make them quite promising for application both on the Earth and in space. Among these are the LHP high heat-transport capacity at an any orientation in the field of mass forces, good mass-and-size parameters and the possibility of an arbitrary configuration of transport lines. At the same time such a drawback of LHPs of the conventional type as the instability of start up and operation in the region of low heat loads reduces their performance. The problem is connected, in a general case, with the unfavourable distribution of the vapor and the liquid phases of the working fluid in the evaporator. There is reason to believe that the LHP operation can also be significantly affected by zero-g conditions, in which the distribution of a working fluid is pre-determined only by the action of surface forces and the thermocapillary phenomena. The paper performs a general analysis of the necessary conditions imposed on the construction of LHP and some designs that contribute to the retention of serviceability in zero-g conditions at low heat loads. It gives the results of laboratory investigations of an adapted ammonia LHP with a heat-transfer capacity up to 2 kWxm

Найти похожие

4.
Инвентарный номер: нет.
   
   H 65


   
    High heat flux loop heat pipes / M. T. North, D. B. Sarraf, J. H. Rosenfeld, Yu. F. Maydanik, S. V. Vershinin // SPACE TECHNOLOGY AND APPLICATIONS INTERNATIONAL FORUM (STAIF-97), PTS 1-3: 1ST CONFERENCE ON FUTURE SCIENCE & EARTH SCIENCE MISSIONS; 1ST CONFERENCE ON SYNERGISTIC POWER & PROPULSION SYSTEMS TECHNOLOGY; 1ST CONFERENCE ON APPLICATIONS OF THERMOPHYSICS IN MICROGRAVITY; 2ND CONFERENCE ON COMMERCIAL DEVELOPMENT OF SPACE; - 2ND CONFERENCE ON NEXT GENERATION LAUNCH SYSTEMS; 14TH SYMPOSIUM ON SPACE NUCLEAR POWER AND PROPULSION, ALBUQUERQUE, 26-30 JAN, 1997 . - 1997. - Vol.387. - С. 561-566
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPES -- THERMAL POWER LOADS -- VAPOR FLOW LOSSES
Аннотация: Loop Heat Pipes (LHPs) can transport very large thermal power loads, over long distances, through flexible, small diameter tubes and against high gravitational heads. While recent LHPs have transported as much as 1500 W, the peak heat flux through a LHP's evaporator has been limited to about 0.07 MW/m(2). This limitation is due to the arrangement of vapor passages next to the heat load which is one of the conditions necessary to ensure self priming of the device. This paper describes work aimed at raising this limit by threefold to tenfold. Two approaches were pursued. One optimized the vapor passage geometry for the high heat flux conditions. The geometry improved the heat flow into the wick and working fluid. This approach also employed a finer pored wick to support higher vapor flow losses. The second approach used a bidisperse wick material within the circumferential vapor passages. The bidisperse material increased the thermal conductivity and the evaporative surface area in the region of highest heat flux, while providing a flow path for the vapor. Proof-of-concept devices were fabricated and tested for each approach. Both devices operated as designed and both demonstrated operation at a heat flux of 0.70 MW/m(2). This performance exceeded the known state of the art by a factor of more than six for both conventional heat pipes and for loop heat pipes using ammonia. In addition, the bidisperse-wick device demonstrated boiling heat transfer coefficients up to 100,000 W/m(2) K, and the fine pored device demonstrated an orientation independence with its performance essentially unaffected by whether its evaporator was positioned above, below or level with the condenser

Найти похожие

5.
Инвентарный номер: нет.
   
   H 65


   
    High heat flux loop heat pipes / M. T. North, D. B. Sarraf, J. H. Rosenfeld, Yu. F. Maydanik, S. V. Vershinin // 6th European Symposium on Space Environmental Control Systems: Noordwijk, Netherlands, 20-22 may 1997 . - 1997. - Vol. 400. - С. 371-376
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPES -- POWER LOADS -- GRAVITATIONAL HEADS
Аннотация: Loop Heat Pipes (LHPs) can transport very large thermal power loads, over long distances, through flexible, small diameter tubes and gravitational heads. While recent transported as much as 1500 W, the peak heat flux through a LHP's evaporator has been limited to about 0.07 MW/m(2). This limitation is due to the arrangement of vapor passages next to the heat load which is one of the conditions necessary to ensure self priming of the device. This paper describes work aimed at raising this limit by threefold to tenfold. Two approaches were pursued. One optimized the vapor passage geometry for the high heat flux conditions. The geometry improved the heat flow into the wick and working fluid. This approach also employed a finer pored wick to support higher vapor flow losses. The second approach used a bidisperse wick material within the circumferential vapor passages. The bidisperse material increased the thermal conductivity and the evaporative surface area in the region of highest heat flux, while providing a flow path for the vapor. Proof-of-concept devices were fabricated and tested for each approach. Both devices operated as designed and both demonstrated operation at a heat flux of 0.70 MW/m(2) This performance exceeded the known state of the art by a factor of more than six for both conventional heat pipes and for loop heat pipes using ammonia. In addition, the bidisperse-wick device demonstrated boiling heat transfer coefficients up to 100,000 W/m(2).K, and the fine pored device demonstrated an orientation independence with its performance essentially unaffected by whether its evaporator was positioned above, below or level with the condenser

Найти похожие

6.
Инвентарный номер: нет.
   
   T 44


   
    The proof-of-feasibility of multiple evaporator loop heat pipes / W. B. Bienert, D. A. Wolf, M. N. Nikitkin, Yu. F. Maydanik, Y. G. Fershtater, S. V. Vershinin, J. M. Gottschlich // 6th European Symposium on Space Environmental Control Systems: Noordwijk, Netherlands, 20-22 may 1997 . - 1997. - Vol.400. - С. 393-398
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPES -- THERMAL CONTROL -- MULTIPLE THERMAL INTERFACE
Аннотация: This paper presents results that demonstrate the proof-of-feasibility of multiple evaporator Loop Heat Pipes (LHP). It was demonstrated that a multiple evaporator LHP can successfully operate as a thermal control system component. A breadboard LHP with multiple evaporators (two) that retained the reliable self starting behavior of the single thermal interface LHP was developed. Program efforts were concentrated on a two pump system and investigated the performance of the dual evaporator LHP. Analytical predictons and experimental test data are compared, and important issues are discussed that will be a baseline for continued development of multiple thermal interface LHPs. All of the conclusions are based on test results, analytic modeling and the correlation of the two. Although a mathematical model that predicts the multiple evaporator LHP behavior was developed, the primary focus of the program was the development, fabrication, and test of a breadboard multi-evaporator LHP. The program clearly demonstrated that multi-evaporator LHPs are feasible and merit further development as a viable thermal control components

Найти похожие

7.
Инвентарный номер: нет.
   
   H 65


   
    High heat flux loop heat pipes / M. T. North, D. B. Sarraf, J. H. Rosenfeld, Yu. F. Maydanik, S. V. Vershinin // 6th European Symposium on Space Environmental Control Systems: Noordwijk, Netherlands, 20-22 may 1997 . - 1997. - Vol. 400. - С. 371-376
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPES -- POWER LOADS -- GRAVITATIONAL HEADS
Аннотация: Loop Heat Pipes (LHPs) can transport very large thermal power loads, over long distances, through flexible, small diameter tubes and gravitational heads. While recent transported as much as 1500 W, the peak heat flux through a LHP's evaporator has been limited to about 0.07 MW/m(2). This limitation is due to the arrangement of vapor passages next to the heat load which is one of the conditions necessary to ensure self priming of the device. This paper describes work aimed at raising this limit by threefold to tenfold. Two approaches were pursued. One optimized the vapor passage geometry for the high heat flux conditions. The geometry improved the heat flow into the wick and working fluid. This approach also employed a finer pored wick to support higher vapor flow losses. The second approach used a bidisperse wick material within the circumferential vapor passages. The bidisperse material increased the thermal conductivity and the evaporative surface area in the region of highest heat flux, while providing a flow path for the vapor. Proof-of-concept devices were fabricated and tested for each approach. Both devices operated as designed and both demonstrated operation at a heat flux of 0.70 MW/m(2) This performance exceeded the known state of the art by a factor of more than six for both conventional heat pipes and for loop heat pipes using ammonia. In addition, the bidisperse-wick device demonstrated boiling heat transfer coefficients up to 100,000 W/m(2).K, and the fine pored device demonstrated an orientation independence with its performance essentially unaffected by whether its evaporator was positioned above, below or level with the condenser

Найти похожие

8.
Инвентарный номер: нет.
   
   P 31


    Pastukhov, V. G.
    Adaptation of loop heat pipes to zero-g conditions / V. G. Pastukhov, Yu. F. Maydanik, Y. G. Fershtater // 6th European Symposium on Space Environmental Control Systems: Noordwijk, Netherlands, 20-22 may 1997 . - 1997. - Vol.400. - С. 385-391
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
LOOP HEAT PIPES -- HEAT-TRANSPORT -- THERMOCAPILLARY PHENOMENA
Аннотация: Loop heat pipes (LHPs) posses a great variety of valuable properties, which make them quite promising for application both on the Earth and in space. Among these are the LHP high heat-transport capacity at an any orientation in the field of mass forces, good mass-and-size parameters and the possibility of an arbitrary configuration of transport lines. At the same time such a drawback of LHPs of the conventional type as the instability of start up and operation in the region of low heat loads reduces their performance. The problem is connected, in a general case, with the unfavourable distribution of the vapor and the liquid phases of the working fluid in the evaporator. There is reason to believe that the LHP operation can also be significantly affected by zero-g conditions, in which the distribution of a working fluid is pre-determined only by the action of surface forces and the thermocapillary phenomena. The paper performs a general analysis of the necessary conditions imposed on the construction of LHP and some designs that contribute to the retention of serviceability in zero-g conditions at low heat loads. It gives the results of laboratory investigations of an adapted ammonia LHP with a heat-transfer capacity up to 2 kWxm

Найти похожие

9.
Инвентарный номер: нет.
   
   M 19


    Maydanik, Yu. F.
    Development and Tests of Miniature Loop Heat Pipe with a Flat Evaporator / Yu. F. Maydanik, S. V. Vershinin, M. A. Chenysheva // SAE 2000 Transaction - Journal of Aerospace. - 2001. - Paper Number: 2000-01-2491
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
AMMONIA MINIATURE -- LOOP HEAT PIPE -- FLAT EVAPORATOR
Аннотация: The paper presents the results of analysis, development and tests of an ammonia miniature loop heat pipe (MLHP) with a flat evaporator, which has an active-zone diameter of 30mm. The length and the diameter of the vapor and the liquid lines are 1m and 2/1.2mm. The device serviceability has been demonstrated at a horizontal and a vertical orientation in 1-g conditions. The maximum heat load achieved on trials was equal, respectively, to 160W and 120W, which corresponds to a heat flow in the evaporation zone of 23 W/cm 2 and 17 W/cm 2 . The minimum thermal resistance at nominal heat loads from 40 to 80 W varied in the range from 0.42 W/m 2 K to 0.59 W/m 2 K. A comparison has been made with a model MLHP with a cylindrical evaporator equipped with a copper and aluminum “sa

Найти похожие

10.
Инвентарный номер: нет.
   
   M 19


    Maydanik, Yu. F.
    Development and Tests of Miniature Loop Heat Pipe with a Flat Evaporator / Yu. F. Maydanik, S. V. Vershinin, M. A. Chenysheva // SAE 2000 Transaction - Journal of Aerospace. - 2001. - Paper Number: 2000-01-2491
ББК 53
Рубрики: ФИЗИКА
Кл.слова (ненормированные):
AMMONIA MINIATURE -- LOOP HEAT PIPE -- FLAT EVAPORATOR
Аннотация: The paper presents the results of analysis, development and tests of an ammonia miniature loop heat pipe (MLHP) with a flat evaporator, which has an active-zone diameter of 30mm. The length and the diameter of the vapor and the liquid lines are 1m and 2/1.2mm. The device serviceability has been demonstrated at a horizontal and a vertical orientation in 1-g conditions. The maximum heat load achieved on trials was equal, respectively, to 160W and 120W, which corresponds to a heat flow in the evaporation zone of 23 W/cm 2 and 17 W/cm 2 . The minimum thermal resistance at nominal heat loads from 40 to 80 W varied in the range from 0.42 W/m 2 K to 0.59 W/m 2 K. A comparison has been made with a model MLHP with a cylindrical evaporator equipped with a copper and aluminum “sa

Найти похожие

 1-10    11-20   21-30   31-40   41-46 
 

Сиглы отделов ЦНБ УрО РАН


  бр.ф. - Бронированный фонд

  бф - Научно-библиографический отдел

  БХЛ - Фонд художественной литературы

  ИИиА -Фонд исторической литературы в ЦНБ УрО РАН

  ИМЕТ -Отдел ЦНБ в Институте металлургии УрО РАН

  кх - Отдел фондов (книгохранениe)

  МБА - Межбиблиотечный абонемент

  мф - Методический фонд

  ок - Отдел научной каталогизации

  оку - Отдел комплектования и учета

  орф - Обменно-резервный фонд

  пф - Читальный зал деловой и патентной информации

  рк - Фонд редкой книги

  ч/з - Главный читальный зал

  эр - Зал электронных ресурсов

  

Сиглы библиотек институтов и НЦ УрО РАН
© Международная Ассоциация пользователей и разработчиков электронных библиотек и новых информационных технологий
(Ассоциация ЭБНИТ)
Яндекс.Метрика